The Siemens SITRANS P320 and SITRANS P420 with Unique Remote Safety Handling


The Siemens SITRANS P320/P420 pressure transmitters are digital pressure transmitters featuring extensive user-friendliness and high accuracy. The parameter assignment is performed using input but- tons or the HART interface.

The "Remote Safety Handling" function saves customers significant amounts of time and money, because the SIL function can be switched on and validated remotely via SIMATIC PDM. This eliminates travel times and on-site operation via the local display or keyboard.

For more information, contact Process Technology, Inc. by visiting https://process-tech.com or by calling 801-264-1114.

SX5-B Safety Laser Scanners from Banner Engineering


Compact and easy-to-deploy, SX5 Series safety laser scanners from Banner Engineering protect personnel, equipment, and mobile systems within a user-defined area. They continuously scan a 275° area to create a two-dimensional protected zone that must be crossed to reach the hazard.

For more information, contact Process Technology, Inc. by visiting https://process-tech.com or by calling 801-264-1114.

Process Instrument Calibration Services from Siemens


Measuring, positioning, recording, and controlling are important parameters in all industries processes. That’s why process instruments need to deliver the highest levels of precision and reliability. 

Siemens, a world leader in engineering and process control instruments, provides off-site and on-site calibration services that keep your plant running at optimum efficiency.

OFF-SITE CALIBRATION SERVICES
Siemens offers factory calibration services for Pressure, Temperature and Flowmeters from both our own and other manufacturers.

ON-SITE CALIBRATION SERVICES
Siemens offers on-site calibrations for Pressure, Temperature and Belt scale of our own products as well as those of other manufacturers.

This video presents the viewer with explanations and concepts for the following:
  • The Siemens Process Instrument Services overview.
  • A description of field instrument technologies.
  • What calibration means.
  • Reasons for calibrating field devices.
  • The importance of calibration and verification.
  • What traceability means.
  • Why accreditation is needed.
  • The Siemens Factory Calibration process.
  • The Siemens On-site Calibration process.
  • What verification means.
  • Reasons for verification.
  • The Siemens On-site Verification process.
For more information, visit https://process-tech.com or call 801-264-1114.

Guided Wave Radar Level Measurement: What's it All About?

When you have a difficult level measurement requirement in a challenging environment, microwave radar technology is often the best solution.

This white paper, courtesy of SIEMENS, is a look at the technology behind this popular application problem solver and what allows it to perform so well in tough conditions: heavy vapors, steam, changing physical and chemical conditions, and high temperatures and pressures.


For more information about guided wave radar level instrumentation, contact Process Technology, Inc. For immediate assistance call 801-264-1114, or visit https://process-tech.com.

The Hazards of NOT Using Softstarters on Your Beverage Line


This video demonstrates a key advantage of using a soft start system on a bottling line, in this case a dairy milk line. Consistent start-up regardless of belt load and reduced product damage risk (illustrated by this video) are obvious. Another important benefit is that couplings, belts and bearings are given additional protection against mechanical wear.

Softstarters from ABB increase the life of a motor by protecting the motor against electric stress. They do so by optimizing starting currents that put a great deal of stress on the motor with conventional start methods. Installation-friendly Softstarters from ABB can reduce your assembly and start time by being easy to use and easy to learn. A single Softstarter provides a compact and complete starting solution with everything you need in a single system, from the bypass contactor to the overload protection. In addition, ABB Softstarters can ultimately help increase productivity with many application-specific features.

For more information about ABB Softstarters, contact Process Technology, Inc. by calling 801-264-1114 or visit https://process-tech.com.

The Unique Challenges of Measuring Steam Usage for Colleges and Universities

ExactSteam V-Cone Flowmeter
ExactSteam™ V-Cone® Flowmeter
Steam poses a unique challenge for colleges and universities.

Many schools want to accurately track, and then internally bill, for steam usage in each of their buildings as part of a wider effort to improve resource management. However, traditional steam metering technologies tend to be a less than optimal choice.

Most times, it’s necessary to place campus steam meters in the basements of buildings where there isn’t a lot of room for piping. That causes issues because flow meters typically require significant runs of straight pipe upstream and downstream of the meter to work correctly.

School administrators also encounter issues by trying to measure steam usage during the low-demand summer months. Common vortex meters, which contain a shedder bar mounted across the diameter of a pipe to measure flow, work well at higher flows. When it comes to low flows, however, they can stop working completely (i.e., low flow cutoff problems). Differential pressure (DP) flow meters coupled with the proper electronics, by comparison, can push the low flow cutoff value downward. However, most DP meters can’t get around the straight-run requirements.

McCrometer’s ExactSteam solution is designed to overcome those hurdles.

The ExactSteam V-Cone Flowmeter works well with short straight-pipe runs, so it addresses the lack of space issues faced by colleges and universities. It also measures steam across the entire range, performing better at lower flows.

The High Cost of Low Flow Cutoff

Steam system operators can pay a steep price for generating product that passes through a meter but fails to get measured. Also known as low flow cutoff, those losses are a function of the turndown ratio of flow meters. The ratio — defined as the maximum measurement capability of a device compared to its minimum — dictates how wide a flow spectrum can be measured. On campuses, this creates a major issue because demand for steam in the colder weather can be extremely high compared to off-peak times.

ExactSteam is a DP-style flow meter that can be adjusted for colleges during winter months. It contains McCrometer’s established V-cone flow meter combined with a newer electronics package to aid in the downward adjustment of the turndown ratio. A growing number of college campuses, especially larger schools, are seeing the benefits of ExactSteam and adopting the technology.

Some examples include:

Case Study #1 - An East Coast University Steam Operation


This school designed its system to measure from 84,000 lbs/hr to 8,400 lbs/hr, which accounted for a 10:1 turndown ratio and velocities of 420’/second to 42’/second. After the meter was installed, system operators determined their actual flow range was 20,000 lbs/hr to 1,000 lbs/hr (a 20:1 turndown ratio) and velocities were 100’/second to 5’/second.

Because flow rates were overstated, the university dropped below the low flow cutoff and wasn’t measuring at all during the off-season.

The solution: Purchase another meter with a larger cone that would produce more differential pressure at the correct flows. The school has since installed an ExactSteam V-Cone Flowmeter.

Case Study #2 – A University Hospital Using Both Condensate And Steam Meters


During the winter, the steam meters were always measuring more steam than the condensate meters.  The difference was justified because the condensate meters were not capturing steam usage of the autoclaves.  However, during the summer, the condensate meters were measuring more than the steam meters, which was impossible.

The steam meter was designed for flows from 14,000 lbs/hr to 1,400 lbs/hr.  During the summer months the hospital flows frequently dropped below 1,400 lbs/hr, which was below the low flow cutoff.  It was also determined that their highest flow during the summer was 5,000 lbs/hr.  The hospital needed more turndown and a lower flow range.

The solution: The ExactSteam V-Cone Flowmeter was installed.  It was designed for flows from 6,000 lbs/hr to 300 lbs/hr and was able to fit in the basement between two elbows.

Well Positioned For Campus Use

Key aspects of McCrometer’s ExactSteam solution include: a complete flow meter for steam metering, factory-configured for energy metering or mass flow; the ability to measure saturated (dry), superheated, and unsaturated (wet) steam; the V-Cone acts as its own flow conditioner by disrupting all centralized flow disturbances; signal stability allows it to measure a wider range of flow than other meters, minimizing pressure loss; and minimum installation requirements, so retrofitting and new installations are easier.

Because of the inherent conflicts, traditional steam metering technologies are not a good fit for many colleges and universities. However, there are solutions available to campus steam system operators to capture readings from most — if not all — of their steam production, even in less than ideal conditions.

For more information about measuring steam usage on campuses and universities, contact Process Technologies, Inc. by calling 801-264-1114 or by visiting their web site at https://process-tech.com.

Reprinted with permission from McCrometer.